MedicineCardiologyBiomedical ImagingDiagnostic ImagingMolecular ImagingCardiac ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingTissue Perfusion AssessmentBlood FlowBlood Flow DynamicsFlow Heterogeneity AssessmentMolecular Marker ApplicationsMolecular Marker DetectionQuantitative AutoradiographyQuantitative Myocardial Perfusion ImagingSpatial Cellular Heterogeneity
OBJECTIVE: Provide regional flow measurement in the hearts of small mammals using a new, higher-resolution technique based on the deposition of a molecular marker. METHODS: We determined the instantaneous extraction and retention of the "molecular microsphere" radiolabeled desmethylimipramine in retrogradely perfused hamster hearts. In a separate series of experiments, autoradiography was used to measure regional myocardial deposition densities in hamster hearts of about 0.5 g with spatial area resolution of 16 x 16 microns. RESULTS: Radiolabeled desmethylimipramine is almost 100% extracted during a single transcapillary passage and is retained in the tissue for many minutes. Autoradiographic images demonstrated a spatial flow heterogeneity with standard deviations of 31 +/- 4% of the mean flow (N = 5) in 16 x 16 x 20-micronm3 voxels. This is equivalent to the projections made using fractal relationships from cruder observations obtained with microspheres in the hearts of baboons, sheep, and rabbits. CONCLUSIONS: Autoradiography using a molecular deposition marker provides quantitative information on myocardial flow heterogeneities with resolution at the size of cardiac myocytes. Because the regions resolved are smaller than the volume of regions supplied by single arterioles, the results must slightly exaggerate the true heterogeneity of regional flows.
22
Louis Sokoloff, Martin Reivich, Charles Kennedy et al. · Journal of Neurochemistry · 1977 · 6K citations
Blood flow measurements with radionuclide-labeled particles
Michaël Heymann, B. Payne, Julien I.E. Hoffman et al. · Progress in Cardiovascular Diseases · 1977 · 2.1K citations
Some sources of error in measuring regional blood flow with radioactive microspheres.
Gerald D. Buckberg, J. Carter Luck, D B Payne et al. · Journal of Applied Physiology · 1971 · 1.1K citations
Medicine, Physiology, Radiology +11
Measurement of regional cerebral blood flow with antipyrine-14C in awake cats.
Martin Reivich, Jane Jehle, Louis Sokoloff et al. · Journal of Applied Physiology · 1969 · 502 citations · Full text