European Journal of Cardio-Thoracic Surgery · 2010 · 78 citations · 6 references
MedicineCardiologySurgeryCardiac TransplantationCardiothoracic SurgeryTransplant SurgeryExtracorporeal CirculationExtracorporeal Life SupportHeart FailureHeart TransplantationHemodynamic SupportMechanical Circulatory SupportBridging Mechanical Circulatory SupportDestination TherapyEnd-stage Heart Failure CareLeft Ventricular Assist Device TherapyLeft Ventricular Assist DevicesPulmonary Capillary Wedge PressureVentricular Assist Device SupportVentricular Ejection Fraction Assessment
OBJECTIVE: Full mechanical support with a left-ventricular assist device (LVAD) is generally limited to end-stage heart-failure patients. We have been studying the safety and efficacy of the partial support Synergy® Pocket Micro-pump as bridge-to-transplant in a less-sick group of patients as a prelude to a study of its use for destination therapy. METHODS: The CircuLite® Synergy device is implanted via a small right-sided thoracotomy with an inflow cannula in the left atrium and an outflow graft connected to the right subclavian artery without the use of extracorporeal circulation. The micro-pump is the size of an AA battery, sits in the 'pacemaker' pocket subcutaneously in the right clavicular groove and pumps up to 3.0 l min⁻¹ from the left atrium to the right subclavian artery. RESULTS: The device has been implanted in 27 patients awaiting cardiac transplant (22 males), age 54.8 ± 10.0 years with ejection fraction (EF) 21 ± 6%, mean arterial pressure 73.5 ± 8.8 mm Hg, pulmonary capillary wedge pressure (PCWP) 27.5 ± 7.8 mm Hg and cardiac index (CI) 2.0 ± 0.4 l min⁻¹ m⁻². Duration of support has ranged from 6 to 281 days. Right-heart catheterization showed significant hemodynamic improvement in the short- and intermediate term after implant, with increases in CI from 2.0 ± 0.4 to 2.8 ± 0.6 l min⁻¹ m⁻² (p < 0.001) and reductions in PCWP from 28 ± 6 to 18 ± 7 mm Hg (p = 0.002) at an average of 9.5 ± 5.5 weeks. CONCLUSIONS: The Synergy device provides partial hemodynamic support and its use is associated with significantly improved hemodynamics, thus appearing to interrupt and partially reverse the progressive hemodynamic deterioration typical of end-stage heart failure. Ongoing efforts are aimed at demonstrating additional clinical benefits and continuing to further improve the risk/benefit ratio.
6
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Leslie W. Miller, Francis D. Pagani, Stuart D. Russell et al. · New England Journal of Medicine · 2007 · 1.7K citations · Full text
Medicine, Cardiology, Surgery +16
Bart Meyns, Stefan Klotz, André Simon et al. · Journal of the American College of Cardiology · 2009 · 352 citations