Electrochemical and Solid-State Letters · 2005 · 173 citations · 17 references
EngineeringChemical EngineeringMaterials ScienceElectrochemical EngineeringElectrochemistryMembrane ScienceElectrochemical CellsElectrochemical KineticsFuel Cell MaterialsFuel Cell MembranesFuel CellsMembrane EngineeringDegradationFuel Cell DegradationHumidificationMembrane DegradationPerformance DegradationPolarization CurvesProton Exchange Membrane Fuel CellsProton Exchange Membranes
A 2700 h life test of a single proton exchange membrane fuel cell (PEMFC) with Nafion 112 membrane under nonsaturated humidification was conducted. In situ measurements of hydrogen crossover rate through the membrane and electrochemical active surface area (EAS) of Pt catalyst, in combination with cell polarization curves, were applied to investigate the degradation mechanism. A slow decrease of the EAS of Pt catalyst from 400 to 1900 h running was found to cause a slight voltage decay only at high current densities. However, a subsequent dramatic degradation of the membrane results in an accelerated collapse of the fuel cell. © 2005 The Electrochemical Society. All rights reserved.
17
Materials for fuel-cell technologies
Brian Steele, Angelika Heinzel · Nature · 2001 · 7.7K citations
Natural Sciences, Materials Engineering, Materials Science +12
Aging mechanisms and lifetime of PEFC and DMFC
Shanna Knights, Kevin Michael Colbow, Jean St‐Pierre et al. · Journal of Power Sources · 2003 · 744 citations
Natural Sciences, Chemical Engineering, Materials Science +7