High Gradient Study at KEK on X-Band Accelerator Structure for Linear Collider

T. Higo, M. Akemoto, Atsushi Enomoto, Shigeki Fukuda, H. Hayano, Norio Kudo, Shuji Matsumoto, T. Saeki, N. Terunuma, N. Toge,

Proceedings of the 2005 Particle Accelerator Conference · 2006 · 10 citations · 1 references

Concepts

Abstract

This paper describes the high-field studies on accelerator structures conducted at the X-band Test Facility, XTF, which was commissioned at KEK in 2004. A 60cm-long structure built at KEK has been processed in 2004-2005, with an accumulated operation time with the RF turned on of ∼ 1000 hours. The RF breakdown rate of this structure at 65MV/m with 400nsec flat pulses was initially measured to be ∼ once per 0.2×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sup> pulses, and decreased to ∼ once per 0.7×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sup> pulses with the processing. This latter breakdown rate satisfies the stability requirement for use of such accelerator structures at the linear collider. The high-power performance of two more 60cm structures will be measured in 2005. These studies are expected to provide benchmark performance data of accelerator structures in both high-gradient and medium-gradient operations, such as those envisaged in applications to compact X-band accelerators.

References

1