The ion current collected by a probe biased at the cathode potential and located behind an annular anode of a vacuum arc is measured as a function of distance to the cathode and background argon pressure. The arc is formed between a circular Cu cathode and an annular anode. Arc current is 170 A, and the arc duration is 0.9 s. The arc is ignited by momentary contact of a movable W trigger rod (held at anode potential) with the cathode. Arc voltage, arc current, and ion current are measured using an analog data acquisition card and a personal computer. Arc voltage and arc current values are stable during the arc and their normalized standard deviation is less than 0.07. Ion current is noisy and fluctuates during the arc with a normalized standard deviation that varies from 0.5 at p<0.1 torr up to more than 1.5 at p>1 torr.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
23
Components of cathode erosion in vacuum arcs
J.E. Daalder · Journal of Physics D Applied Physics · 1976 · 369 citations