SPECT: Single Photon Emission Computed Tomography

R.J. Jaszczak, R. Edward Coleman, C. B. Lim

IEEE Transactions on Nuclear Science · 1980 · 119 citations · 79 references

Concepts

TL;DR

SPECT has regained interest due to advances in CT, yet it faces challenges such as limited photon flux from dose constraints and internal gamma‑ray attenuation, and its potential is enhanced by new radiopharmaceuticals. This paper reviews SPECT’s history, physical attributes, solutions to its inherent problems, and design approaches for high‑quality, artifact‑free reconstructed images. The authors examine SPECT’s physical characteristics, discuss strategies to overcome photon‑flux and attenuation limitations, and evaluate design methods for producing artifact‑free images. Recent progress includes high‑efficiency systems with large detectors and multiple scanners, improved attenuation‑correction techniques, and ongoing work toward absolute regional radionuclide quantification over time.

Abstract

Interest in single photon emission computed tomography (SPECT) has been renewed as a result of the successful application of transmission (x-ray) CT to diagnostic radiology. Many aspects of SPECT are different from those encountered in transmission CT, and often are more difficult to overcome. Examples of two major aspects encountered are 1) the limitations on the available photon flux imposed mainly by dose considerations to the patient and, 2) the internal attenuation of gamma rays within the patient prior to detection. Progress has been made recently in overcoming the quantum limitation by designing SPECT systems using special collimation and large active detector areas. High efficiency systems have been designed and built using both multiple-scanners and also using multiple large-field-of-view scintillation cameras. Much progress has also been made in compensating for the problem of gamma ray attenuation using iterative and analytical approaches. This paper reviews the history of single photon emission tomography, characterizes the physical attributes of SPECT, describes some solutions to the inherent problems encountered, and also reviews a few selected approaches in designing SPECT systems to provide high quality, artifact-free reconstructed images. It is anticipated that future developments will allow SPECT systems to more nearly attain the ultimate goal of determining absolute regional radionuclide concentration as a function of time. These systems, coupled with newly developed physiological radiopharmaceuticals, can provide useful research and clinical information.

References

79