IEEE Transactions on Biomedical Engineering · 2001 · 105 citations · 18 references
EngineeringBioengineeringDevelopmental BiologyBiomemsEmbryo TransferIn Vitro FertilizationEmbryo HandlingEmbryo TransportMicrofluidic DevicesMicrofluidic SystemsMicrofluidic TransportMicrofluidicsCell Transport In MicrofluidicsFabricationMicrochannel DesignMicrochannel HydrodynamicsMicrofluidic Culture SystemsMicrofluidic Embryo CultureMicrofluidic FabricationMicrofluidic Flow
We have designed, built, and tested microfluidic systems capable of transporting individual, preimplantation mouse embryos (100-microm to 150-microm diameter) through a network of channels. Typical channels are 160 to 200 microm deep, 250 to 400 microm wide at the top, and narrower at the bottom (0 to 250 microm wide) due to the fabrication process. In these channels, a pressure gradient of 1 Pa/mm causes the medium to flow on the order of 10(-10) m3/s (100 nl/s), with an average speed of 1 to 2 mm/s. Under these flow conditions the embryos roll along the bottoms of the channels, traveling at 1/2 the speed of the fluid. By manipulating the pressure at the wells connected to the ends of the channels, the embryos can be transported to (and retained at) specific locations including culture compartments and retrieval wells.
18
The anatomy and physiology of pre-attachment bovine embryos
K. Betteridge, J.E. Fléchon · Theriogenology · 1988 · 255 citations
Superovulation and Embryo Transfer in Cattle
G.E. Seidel · Science · 1981 · 183 citations