Computational studies of the effects of oxidiser injector length on combustion instability

Randolph Smith, Guoming Xia, William Anderson, Charles Merkle

Combustion Theory and Modelling · 2011 · 27 citations · 30 references

Concepts

Abstract

Computational analyses of the effects of oxidiser injector length on combustion instability in a choked high pressure combustor are described. The configuration is based on companion experiments using gaseous methane and decomposed hydrogen peroxide as reactants. The generic behaviour of one injector length is first investigated in detail to investigate the general character of the flow-fields. Comparisons between computation and experiment are then given for five lengths. The predictions for the intermediate lengths are in good agreement with the experiments in terms of most unstable frequency, its amplitude and the rate of decay of higher harmonics. The computations for the shortest injector predict the second mode is most unstable whereas the experiment indicates the fundamental was more unstable. At the longest length the computations show a character similar to the other lengths, while the experiments indicate the instability jumps to much higher frequencies that did not appear in the computations. A series of post-processing diagnostics is used to assess the mechanisms causing instability and to give possible explanations for the experimental behaviour.

References

30