Heart · 2008 · 291 citations · 29 references
MedicineCardiologyRadiologyCardiothoracic RadiologyClinical CardiologyInterventional RadiologyCardiac AssessmentCardiac CatheterizationCardiovascular ImagingCoronary AngiographyCoronary Artery DiseaseCoronary Artery ImagingComputed Tomography Coronary AngiographyConventional AngiographyCoronary Artery Disease DetectionCoronary Artery Stenosis AssessmentCoronary Ct AngiographyCoronary Lesion AssessmentCoronary Stenosis AssessmentHeart Rate
OBJECTIVE: To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). DESIGN, SETTING AND PATIENTS: Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean (SD) age 68 (9) years, mean (SD) body mass index 26.2 (3.2) kg/m2). All study participants underwent DSCT in the SAS mode and CCA within 14 days. Twenty-seven patients were given intravenous beta blockers for heart rate reduction before CT. Patients were excluded if a target heart rate <or=70 bpm could not be achieved by beta blockers or when the patients were in non-sinus rhythm. Two blinded readers independently evaluated coronary artery segments for assessability and for the presence of significant (>50%) stenoses. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) were determined, with CCA being the standard of reference. Radiation dose values were calculated. RESULTS: DSCT coronary angiography in the SAS mode was successfully performed in all 120 patients. Mean (SD) heart rate during scanning was 59 (6) bpm (range 44-69). 1773/1803 coronary segments (98%) were depicted with a diagnostic image quality in 109/120 patients (91%). The overall patient-based sensitivity, specificity, PPV and NPV for the diagnosis of significant stenoses were 100%, 93%, 94% and 100%, respectively. The mean (SD) effective dose of the CT protocol was 2.5 (0.8) mSv (range 1.2-4.4). CONCLUSIONS: DSCT coronary angiography in the SAS mode allows, in selected patients with a regular heart rate, the accurate diagnosis of significant coronary stenoses at a low radiation dose.
29
Austen Wg, Je. Edwards, RL Frye et al. · Circulation · 1975 · 3.3K citations · Full text
Medicine, Cardiology, Surgery +17
First performance evaluation of a dual-source CT (DSCT) system
Thomas Flohr, Cynthia H. McCollough, Herbert Bruder et al. · European Radiology · 2005 · 1.4K citations
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Sebastian Leschka, Hatem Alkadhi, André Plass et al. · European Heart Journal · 2005 · 963 citations · Full text
Medicine, Cardiology, Radiology +17