IEEE Transactions on Power Electronics · 1999 · 11 citations · 15 references
EngineeringElectrical EngineeringLow-power DesignPower ElectronicsProcess ControlPower System StabilityRobust ControlVoltage RegulationContinuous Conduction Mode OperationDc-link Voltage ControlDiscontinuous Conduction Mode OperationHigh-power-factor ConversionLight-load OperationLoadRobust PerformanceRobust Stability
This paper presents a robust-controlled single-stage converter (SSC) operating either in discontinuous conduction mode (DCM) or in continuous conduction mode (CCM) to achieve high power factor for universal line voltage range from 90 to 264 V/sub rms/. At light load, the proposed system is operated in the DCM, while at heavy load the system is operated in the CCM, thus, the DC-link voltage can be properly controlled within a certain voltage range and the efficiency can be improved as well. The overall system is with a robust controller and is operated in a fixed frequency. In the design, the load variation and line voltage variation are treated as plant uncertainty and control disturbance, respectively. The H/sup /spl infin// robust control method is adopted to design a proper robust controller to achieve robust stability and robust performance. The measured results from a prototype have confirmed the effectiveness and feasibility of the proposed system.
15