IEEE Transactions on Industry Applications · 2003 · 45 citations · 2 references
EngineeringMechanical EngineeringHeat TransferThermal AnalysisThermodynamicsInduction MachinesMachine CoolingMachine TestingTemperature MeasurementThermal ManagementThermal StressesExperimental Thermal TestingInduction MotorsLoadingsMotor CoolingStator Thermal AnalysisTemperature Rise AnalysisTemperature Rise TestingThermal Management Of Electric Machines
There are many applications of induction motors to cyclic loading. Most motor manufacturers will perform calculations to obtain motor stator temperature rise for variable-load and cyclic loadings based on data provided. This paper is a report of a testing program on totally enclosed fan-cooled induction motors where temperatures for loadings are measured.
2