2008 · 12 citations · 1 references
EngineeringElectrical EngineeringDigital StrategyPower ElectronicsProcess ControlControl System DesignControl SystemsControl TheoryDc-ac InvertersFrequency RegulationPulse-width ModulationDelay ControlDelay EffectsDigital ControlDigital Control Of Dc-dc ConvertersDigital Control Of Power ConvertersDigital Control SystemsInverter ControlInverter Systems
The traditional PID control strategy which is realized in digital method canpsilat achieve better performance than that in analog control. The reason was analyzed why the digital process influences the digital controlled PWM inverterpsilas performance in this paper. One is the process of the zero-order hold. Another one is one-step-delay control which is usually adopted in digital control. Three aspects were analyzed in which influence the digital controlled PWM inverterpsilas performance: (1) how the process of zero-order-hold effects the open-loop frequency property of the digital controlled inverter system (2) how the process of zero-order-hold effects the systempsilas stability (3) how the one-step-delay control effects the systempsilas stability. On the base of setting up discrete mathematical model of the digital controlled inverter system, theory deduction and simulations were done in the condition of P regulator Relevant experiments verify the rightness of the analysis and direction for the design of the digital controlled PWM inverter were given. Finally relevant experiments verify the theoretical analysis.
1