Clinical and Experimental Ophthalmology · 2010 · 34 citations · 17 references
MedicineOphthalmologySurgeryMicrosurgeryOphthalmic SurgeryRefractive SurgeryCataract SurgeryGlaucomaGlaucoma SurgeryIntraocular Pressure MeasurementOcular ImplantsRetinal SurgeryAnti-glaucoma Ocular ImplantsAntiglaucoma TherapyCataract Surgery ComplicationsGlaucoma After Cataract SurgeryIntraocular Pressure Control After SurgeryIntraocular Pressure ReductionPostoperative Visual AcuitySurgical Outcomes In Glaucoma
BACKGROUND: To report the safety and efficacy of Ex-PRESS(TM) miniature glaucoma implant under a scleral flap in patients with previous ocular surgeries. DESIGN: Retrospective, non-comparative case series from a tertiary care hospital. PARTICIPANTS: Patients with previous cataract or failed glaucoma surgeries who had undergone implantation of the Ex-PRESS(TM) miniature glaucoma implant (R-50 and T-50), under a scleral flap, with a minimum of 1-year postoperative follow up. METHODS: For postoperative outcome, success was defined as complete if intraocular pressure (IOP) was 5-21 mmHg without medication or surgical intervention, and qualified if intraocular pressure was within the same range with glaucoma medication. To compare the outcome between patients who had previous trabeculectomy or cataract surgery the definition of success was intraocular pressure of 5-15 mmHg. MAIN OUTCOME MEASURES: Intraocular pressure, number of antiglaucoma drugs, visual acuity and complications. RESULTS: One hundred eyes (100 patients; mean age: 77.4 years) with a mean follow-up period of 27 ± 13.2 months (range: 12-66) were considered. Success was complete in 60 (60%) and qualified in 24 (24%) eyes. The mean preoperative IOP of 27.7 ± 9.2 mmHg (range: 14-52 mmHg) with 2.73 ± 1.1 drugs declined to 14.02 ± 5.1 mmHg with 0.72 ± 1.06 drugs at the last follow up (P < 0.0001). Causes of failure were uncontrolled intraocular pressure (11%), bleb needling (4%) and persistent hypotony (1%). The probability of success in the patients with previous cataract surgery and trabeculectomy at 3 years was 60.6% and 50.9%, respectively. CONCLUSIONS: The Ex-PRESS(TM) implant under scleral flap was a safe and effective glaucoma surgery in the eyes with prior ocular surgery.
17
Three-Year Follow-up of the Tube Versus Trabeculectomy Study
Steven J. Gedde, Joyce Schiffman, William J. Feuer et al. · American Journal of Ophthalmology · 2009 · 376 citations
Implantation of a Miniature Glaucoma Device Under a Scleral Flap
Elie Dahan, Trevor Carmichael · Journal of Glaucoma · 2005 · 188 citations
Medicine, Ophthalmology, Surgery +16