Powering a Ventricular Assist Device (VAD) With the Free-Range Resonant Electrical Energy Delivery (FREE-D) System

Benjamin H. Waters, Alanson P. Sample, Pramod Bonde, Joshua R. Smith

Proceedings of the IEEE · 2011 · 169 citations · 15 references

Concepts

TL;DR

Wireless power technology can eliminate the wired power connection that causes complications in ventricular assist devices, but existing transcutaneous energy transfer systems are limited by short range, misalignment sensitivity, and low efficiency. The study aims to integrate a free‑range resonant electrical delivery system into VADs to make implantable devices a more viable option for heart‑failure patients than transplantation. The FREE‑D system uses magnetically coupled resonators with adaptive frequency tuning and multiple configurations to achieve efficient, robust power transfer across distances and orientations to implanted axial and centrifugal pumps. Laboratory tests demonstrate continuous operation of both pump types with the FREE‑D system, achieving wireless power transfer efficiencies exceeding 90 %.

Abstract

Wireless data communication technology has eliminated wired connections for data transfer to portable devices. Wireless power technology offers the possibility of eliminating the remaining wired connection: the power cord. For ventricular assist devices (VADs), wireless power technology will eliminate the complications and infections caused by the percutaneous wired power connection. Integrating wireless power technology into VADs will enable VAD implants to become a more viable option for heart failure patients (of which there are 80 000 in the United States each year) than heart transplants. Previous transcutaneous energy transfer systems (TETS) have attempted to wirelessly power VADs ; however, TETS-based technologies are limited in range to a few millimeters, do not tolerate angular misalignment, and suffer from poor efficiency. The free-range resonant electrical delivery (FREE-D) wireless power system aims to use magnetically coupled resonators to efficiently transfer power across a distance to a VAD implanted in the human body, and to provide robustness to geometric changes. Multiple resonator configurations are implemented to improve the range and efficiency of wireless power transmission to both a commercially available axial pump and a VentrAssist centrifugal pump [3]. An adaptive frequency tuning method allows for maximum power transfer efficiency for nearly any angular orientation over a range of separation distances. Additionally, laboratory results show the continuous operation of both pumps using the FREE-D system with a wireless power transfer efficiency upwards of 90%.

References

15