The Influence of Sample Collection Methodology and Sample Preprocessing on The Blood Metabolic Profile

35

Citations

27

References

2015

Year

Abstract

The profiles of polar metabolites were significantly dependent on the type of the sample, while lipid profiles were similar in serum and different types of plasma. Extended storage of plasma at room temperature resulted in degradation of lipids already after 1 day. Serum clotting at room temperature generally resulted in higher metabolite concentration compared with serum clotting on ice.