IEEE Transactions on Plasma Science · 2011 · 11 citations · 26 references
EngineeringEnvironmental EngineeringEnvironmental SciencesEnvironmental RemediationWastewater TreatmentWater TreatmentBiological Treatment ProcessesEffluent TreatmentPathogen RemovalWastewater BiotreatmentWastewater PollutionWater PollutionBiological Wastewater TreatmentCorona Discharge TreatmentCorona TreatmentElectrohydraulic SystemsEscherichia ColiOzonationOzonePathogen Removal In Water Treatment
River water cleaning from microorganisms using electrohydraulic discharges and ozonation was investigated. The processed water was highly polluted with the total number of microorganisms (70 400 cfu/mL) and total Escherichia coli bacteria (280 cfu/mL). The processing was conducted in a tube reactor with a hollow needle-rod electrode configuration. A 400-mL sample of river water was treated at different flow rates. Ozonation was performed in a washing bottle with an ozone concentration of 20 g/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> . The corona discharge treatment showed a steady decrease of bacteria and microorganisms but did not kill them completely. Spark discharge killed the bacteria and microorganisms completely; however, its energy efficiency was much lower than that of ozonation. The ozone treatment decreased the concentration of microorganisms and coli bacteria down to 785 and 10 cfu/mL, respectively, in 45 s which resulted in higher energy efficiency than processing using corona and spark discharges. The NPOC analysis of the treated samples showed its concentration of 5 ± 0, 4 ppm in all samples.
26