IEEE Transactions on Information Technology in Biomedicine · 2010 · 106 citations · 19 references
EducationPhysical MedicineAssistive TechnologyMovement AnalysisRehabilitationAction RecognitionMotion CaptureMotion SensorsPostureWearable BiosensorsWearable Health TechnologiesAccelerometer SensorsAccelerometersActivity MonitoringHuman Activity RecognitionPosture MonitoringReal-time ProcessingWearable DevicesWearable Health Monitoring
Triaxial accelerometers enable activity and posture assessment for rehabilitation and elderly surveillance, and recent miniaturized wearable devices integrated into garments allow real‑time remote monitoring of workers and emergency operators in harsh environments. The study introduces an algorithm that detects human posture and activity levels in real time from a single wearable triaxial accelerometer. The algorithm operates independently of sensor orientation, assigns a reliability score to each classification to trigger alarms only under confirmed dangerous conditions, and was evaluated on a custom device to determine the computational resources required for real‑time operation. The algorithm achieved 96.2% accuracy in classifying both static and dynamic activities.
Assessment of human activity and posture with triaxial accelerometers provides insightful information about the functional ability: classification of human activities in rehabilitation and elderly surveillance contexts has been already proposed in the literature. In the meanwhile, recent technological advances allow developing miniaturized wearable devices, integrated within garments, which may extend this assessment to novel tasks, such as real-time remote surveillance of workers and emergency operators intervening in harsh environments. We present an algorithm for human posture and activity-level detection, based on the real-time processing of the signals produced by one wearable triaxial accelerometer. The algorithm is independent of the sensor orientation with respect to the body. Furthermore, it associates to its outputs a "reliability" value, representing the classification quality, in order to launch reliable alarms only when effective dangerous conditions are detected. The system was tested on a customized device to estimate the computational resources needed for real-time functioning. Results exhibit an overall 96.2% accuracy when classifying both static and dynamic activities.
19
Dean M. Karantonis, Michael R. Narayanan, M. Mathie et al. · IEEE Transactions on Information Technology in Biomedicine · 2006 · 1.2K citations
Engineering, Health Informatics, Mechatronics Engineering +17
Erik K. Antonsson, Robert W. Mann · Journal of Biomechanics · 1985 · 568 citations
Education, Physiology, Biomechanics +11