Clinical Oral Implants Research · 2015 · 12 citations · 12 references
DentistryImplant DentistryProsthodonticsImplant ProsthodonticsMaxillofacial ProsthodonticsProstheticsFixed Prosthesis MaintenanceImmediate Implant LoadingImplant-supported Fixed ProsthesesMaxillofacial ProstheticsProsthodontic RehabilitationRetention For Maxillofacial ProsthesesImplant-retained Maxillary ProsthesesMarginal Bone Loss AnalysisMarginal Bone Loss AssessmentMarginal Bone Loss EvaluationMaxillary Fixed ProsthesesPocket Depth MeasurementPocket Depth ReductionProbing Pocket Depth
PURPOSE: The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years. MATERIAL AND METHODS: Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed. RESULTS: Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was -0.34 mm (SD of -0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed. CONCLUSIONS: It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations.
12
Clinical evaluation of small-diameter ITI implants: a prospective study.
Barbara Zinsli, Tanja Sägesser, Ernoe Mericske et al. · PubMed · 2004 · 262 citations
Paulo Maló, Miguel de Araújo Nobre, Armando Lopes et al. · Clinical Implant Dentistry and Related Research · 2011 · 252 citations