ComputingRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyMedical Image AnalysisMedical Volume VisualizationVolume EstimationVolume MeasurementVolume SegmentationVolumetric Visualization3D Medical Image AnalysisGradient-based Edge DetectionIntracranial Aneurysm ImagingQuantitative Volume MeasurementThree-dimensional Volume MeasurementThree-dimensional Volumetric AnalysisVolume CalculationVolume Quantification
Manual volume measurement of intracranial aneurysms from 3D rotational angiography varies on different threshold settings and, therefore, is operator-dependent. We developed and validated a method based on automatic gradient edge detection that is independent on threshold settings and provides an accurate and reproducible volume measurement. This method was compared with manual volume calculation in 13 aneurysm phantoms, and the results were significantly more accurate.
8