Review of Scientific Instruments · 2010 · 17 citations · 6 references
EngineeringNuclear EngineeringNuclear InstrumentationNuclear PhysicsRadiation TransportAccelerator PhysicsNeutron DetectionNuclear FusionAdvanced Beam InjectorsBeam Extraction SystemsBeam InjectorsIon Source DesignIon Source Physics
A deuteron radio frequency quadrupoles injector h has been developed at Peking University. A permanent magnetic electron cyclotron resonance (ECR) ion source is used in the injector system. A 50 keV 100 mA proton beam has been extracted from the ECR ion source and the measured normalized rms emittance is 0.11-0.14pi mm mrad. A deuteron beam has also been extracted at 50 kV with 83 mA total current and its emittance is less than 0.18pi mm mrad. The proton beam transmission has been investigated on a low energy beam transport test bench, and up to 93% transmission can be reached. The new injector with two solenoids has been designed and is being constructed. All the development results will be presented in this paper.