Radiology · 2002 · 77 citations · 15 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyImaging AssessmentMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingMusculoskeletal ImagingMusculoskeletal RadiologyImage Acquisition QualityMagnetic ResonanceMuscle Magnetic Resonance ImagingMusculoskeletal Magnetic Resonance ImagingPaired T-testSignal-to-noise RatioT1-weighted ImagingT2-weighted Imaging
PURPOSE: To compare fat suppression methods by using spectrally selective fat saturation and section-selective water excitation in standard magnetic resonance (MR) imaging sequences used in day-to-day musculoskeletal practice. MATERIALS AND METHODS: Eighty-three patients underwent MR examination with a 1.5-T system. The two methods were compared by using three common sequences: T1-weighted spin-echo (SE) imaging performed after contrast material injection (n = 24), intermediate-weighted fast SE (n = 36) imaging, and T2-weighted fast SE (n = 36) imaging. Acquisition times of the sequences and signal-to-noise and contrast-to-noise ratios of bone, muscle, fat, and water for the two methods were compared quantitatively. Images were then qualitatively reviewed by two radiologists who were blinded to the type of fat suppression used. Image quality was scored according to four criteria (homogeneity of fat suppression, susceptibility and foldover artifacts, conspicuousness of lesion, and overall image quality) by using a five-point scale (0, bad; 1, poor; 2, fair; 3, good; and 4, excellent). A paired Student t test was used to compare the quantitative data, and a nonparametric paired-data Wilcoxon signed rank test was used for qualitative analysis. RESULTS: Water excitation allowed a substantial decrease in acquisition time (by up to 50%) for T1-weighted sequences. Quantitative measurements revealed a greater signal-to-noise ratio (P <.01) with water excitation for all three sequences, whereas the contrast-to-noise ratio was greater with water excitation only in intermediate-weighted sequences (P <.01). Qualitatively, water excitation proved statistically better than or equal to fat saturation for all criteria in all imaging sequences (P <.05). Mean scores of overall image quality ranged between 2.5 and 3.0 for fat saturation and 3.4 and 3.7 for water excitation, respectively (P <.05). CONCLUSION: Section-selective water excitation is faster than conventional fat saturation and produces images of better quality.
15
The rician distribution of noisy mri data
Hákon Guðbjartsson, Samuel Patz · Magnetic Resonance in Medicine · 1995 · 2.5K citations
Fast Spiral Coronary Artery Imaging
Craig H. Meyer, Bob S. Hu, Dwight G. Nishimura et al. · Magnetic Resonance in Medicine · 1992 · 885 citations
Medicine, Cardiology, Radiology +14
Simultaneous spatial and spectral selective excitation
Craig H. Meyer, John M. Pauly, Albert Macovskiand et al. · Magnetic Resonance in Medicine · 1990 · 503 citations
Measuring signal-to-noise ratios in MR imaging.
Leo Kaufman, David Kramer, L E Crooks et al. · Radiology · 1989 · 362 citations