Surgical salvage of microcatheter-induced aneurysm perforation during coil embolization.

12

Citations

6

References

2002

Year

Abstract

We report a case of iatrogenic aneurysm rupture during coil embolization in a 55-year-old woman. Surgical intervention resulted in a good clinical outcome. To our knowledge, this technique for the salvage of catheter-induced aneurysm perforation has not been previously reported.