Journal of Structural Engineering · 1990 · 51 citations · 3 references
EngineeringCivil EngineeringBuilding StructuresStructural AnalysisStructural EngineeringReinforced Concrete StructuresStrength Of MaterialsStructural AssessmentStructural LoadsStructural Response AnalysisStructural TestingCracking BehaviorDisplacementEccentricityOpeningsReinforced ConcreteUltimate Load AnalysisUltimate LoadsUltimate Strength Analysis
Test results of 12 reinforced concrete (RC) wall panels with openings are presented. The panels have been subjected to in‐plane vertical loads applied at an eccentricity to represent possible accidental eccentricity that occurs in practice due to constructional imperfections. The 12 specimens consist of two identical groups of six panels each. One group of panels is tested in one‐way in‐plane action (i.e., supported at top and bottom edges against lateral displacement). The second group of panels is tested in two‐way in‐plane action (i.e., supported on all the four edges against lateral displacement). Openings in the panels represent typical door and window openings. Cracking loads, ultimate loads, crack patterns, and lateral deflections of the panels are studied. Empirical methods have been developed for the prediction of ultimate load. Also, lateral deflections, cracking loads, and ultimate loads of identical loads tested under one‐way and two‐way action are compared.
3
Building Code Requirements for Reinforced Concrete
ACI Committee · ACI Journal Proceedings · 1962 · 609 citations