Medicina oral, patología oral y cirugía bucal · 2012 · 73 citations · 20 references
DentistryOral RadiologyOrthodonticsDental RadiologyDiagnostic ImagingMaxillofacial ImagingAnatomical Landmark IdentificationCephalometric AnalysisCephalometric ImagingCephalometric RadiographyRadiographic LandmarksThree-dimensional Cephalometric AnalysisCephalometric Landmark DetectionCephalometric Landmark LocalizationCephalometric Landmark ReliabilityCone Beam Computed Tomography LandmarksInter-observer AgreementInter-observer ReliabilityInter-rater ReliabilityThree-dimensional Cephalometry
OBJECTIVES: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. STUDY DESIGN: Fifteen patients who had a CBCT (i-CAT) as a diagnostic register were selected. To assess the reproducibility on landmark location and the differences in the measurements of two observers at different times, 41 landmarks were defined on the three spatial axes (X,Y,Z) and located. 3.690 measurements were taken and, as each determination has 3 coordinates, 11.070 data were processed with SPSS statistical package. To discover the reproducibility of the method on landmark location, an ANOVA was undertaken using two variation factors: time (t1, t2 and t3) and observer (Ob1 and Ob2) for each axis (X, Y and Z) and landmark. The order of the CBCT scans submitted to the observers (Ob1, Ob2) at t1, t2, and t3, were different and randomly allocated. Multiple comparisons were undertaken using the Bonferroni test. The intra- and inter-examiner ICC's were calculated. RESULTS: Intra- and interexaminer reliability was high, both being ICC ≥ 0.99, with the best frequency on axis Z. CONCLUSIONS: The most reliable landmarks were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. Those with less reliability were the supraorbitals, right zygion and posterior nasal spine.
20
Accuracy of three-dimensional measurements using cone-beam CT
HM Pinsky, S Dyda, RW Pinsky et al. · Dentomaxillofacial Radiology · 2006 · 344 citations
Comparison of cone beam computed tomography imaging with physical measures
SA Stratemann, JC Huang, K. Maki et al. · Dentomaxillofacial Radiology · 2008 · 275 citations