Experimental Evaluation of Cyclically Loaded Reduced Beam Section Moment Connections

Scott L. Jones, Gary T. Fry, Michael D. Engelhardt

Journal of Structural Engineering · 2002 · 180 citations · 10 references

Concepts

TL;DR

The study experimentally investigates radius‑cut reduced beam section (RBS) moment connections for seismic‑resistant steel moment frames. Eight double‑sided specimens, comprising sixteen RBS connections, were fabricated and subjected to a standard quasi‑static cyclic load pattern to assess panel‑zone strength, composite slab behavior, and beam web‑to‑column flange connections. The specimens generally performed well, with seven of eight achieving ≥0.04 rad story drift before 20 % strength loss; weak panel zones yielded the most stable hysteresis at large drifts, composite slabs mitigated lateral‑torsional buckling without increasing bottom‑flange strains, and welding the web to the flange reduced weld‑fracture risk.

Abstract

This paper describes an experimental study on radius cut reduced beam section (RBS) moment connections for use in seismic resistant steel moment frames. The effects of panel zone strength, composite behavior with a concrete slab, and the beam web-to-column flange connection were specifically addressed in these tests. In total, eight double-sided specimens were designed, fabricated, and tested in this study, providing data for sixteen individual RBS connections. Each specimen was subjected to a standard quasi-static cyclic load pattern. Overall, the specimens performed well with seven of the eight achieving total (elastic plus plastic) story drift ratios of at least 0.04 radians in magnitude before experiencing 20% strength degradation. The other test was stopped due to out-of-plane instability after being loaded to 0.03 radians of total story drift. Comparison of the response of specimens with strong panel zones, balanced panel zones, and weak panel zones relative to beam strength led to the conclusion that weak panel zones allow for the most stable hysteretic response at large drift levels. Inclusion of a composite slab in these tests appeared to stabilize the beams against lateral torsional buckling with no consistently detectable increase in the strains in the bottom beam flange. Welding the beam web to the column flange seemed to decrease the likelihood of weld fracture in these specimens.

References

10