Archives of Internal Medicine · 2007 · 569 citations · 60 references
MedicineInternal MedicineHemodynamic ManagementOutcomes ResearchSleep MedicineContinuous Positive Airway PressurePositive Airway Pressure TherapySleep Apnea CareSleep HealthSleep-disordered BreathingSleep-related Breathing DisordersAmbulatory Blood Pressure ControlApnea-hypopnea Index ReductionBlood PressureContinuous Positive Airway Pressure MonitoringEffect SizeObstructive Sleep Apnea TherapyObstructive Sleep Apnea TreatmentSleep Apnea Syndrome
BACKGROUND: Continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea syndrome (OSAS) might lower blood pressure, but evidence from clinical studies is inconsistent, perhaps as a result of small sample size or heterogeneity in study design. This study aimed to assess whether CPAP reduces ambulatory blood pressure in patients with OSAS, to quantify the effect size with precision, and to identify trial characteristics associated with the greatest blood pressure reductions. METHODS: We identified randomized controlled trials of CPAP vs placebo in patients with OSAS specifically reporting 24-hour ambulatory mean blood pressure (MBP). RESULTS: We included a total of 572 patients from 12 randomized controlled trials. According to a random-effects model, the pooled estimate of the effect of the CPAP intervention was a net decrease of 1.69 mm Hg in 24-hour MBP (95% confidence interval, -2.69 to -0.69). Statistical heterogeneity was moderate (I(2) = 41%). Predefined metaregression analyses estimated that 24-hour MBP would decrease by 0.89 mm Hg per 10-point increase in apnea-hypopnea index at entry (P = .006), by 0.74 mm Hg for each increase of 10 arousal events per hour slept (P = .008), and by 1.39 mm Hg for each 1-hour increase in effective nightly use of the CPAP device (P = .01). CONCLUSIONS: Among patients with OSAS, CPAP reduces 24-hour ambulatory MBP, with greater treatment-related reductions in ambulatory MBP among patients with a more severe degree of OSAS and a better effective nightly use of the CPAP device. These reductions in blood pressure are likely to contribute to a better prognosis in terms of adverse cardiovascular events.
60
Bias in meta-analysis detected by a simple, graphical test
Matthias Egger, George Davey Smith, Martin Schneider et al. · BMJ · 1997 · 56.3K citations
Quantifying heterogeneity in a meta‐analysis
Julian P. T. Higgins, Simon G. Thompson · Statistics in Medicine · 2002 · 36.7K citations
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Terry Young, Mari Palta, Jerome A. Dempsey et al. · New England Journal of Medicine · 1993 · 10.2K citations · Full text