Clinical Chemistry and Laboratory Medicine (CCLM) · 1984 · 134 citations · 7 references
Life SciencesBiochemistryImmunologyClinical BiochemistryClinical ImmunologyEnzymologyEnzyme AssaysEnzyme CharacterizationEnzyme DiagnosticsEnzyme-linked Immunosorbent AssayImmunoassay AnalysisImmunoassay DevelopmentBiological Sample StabilityClinical Chemistry AssaysEnzyme ImmunoassaysEnzyme-linked Immunosorbent Assay (Elisa)Immunoassay MethodologyQuantitative DeterminationReference Range DeterminationSample Stability Assessment
A solid phase, enzyme-linked immunoassay is described for the quantitative determination of the complex of human granulocyte elastase (EC 3.4.21.37) with alpha 1-proteinase inhibitor. The assay employs antibody-coated test tubes and it is suitable for routine use in clinical chemistry laboratories. Data for sample stability and test characteristics are given. A reference range of 20-180 micrograms/l elastase in plasma was determined. The diagnostic significance of granulocyte elastase levels in plasma in inflammatory diseases is discussed.
7
Leukocyte Elastase Release during Blood Coagulation
Edward F. Plow · Journal of Clinical Investigation · 1982 · 202 citations · Full text
Medicine, Hematology, Immunology +10
Protein degradation in health and disease.
D.F. Evered, Julie Whelan · 1980 · 100 citations