Journal of Bone and Joint Surgery - British Volume · 2007 · 183 citations · 26 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone AugmentationBone GraftingOrthopedicsAllograft ReconstructionAutogenous Bone GraftsBone Graft ComplicationsBone ReconstructionComplications Of ArthroplastyHip ArthroplastyAcetabular CoverageAcetabular LooseningAllograft Bone GraftingAseptic Loosening AssessmentAugmented Acetabular ReconstructionImpaction Bone Grafting
We reviewed the results of 71 revisions of the acetabular component in total hip replacement, using impaction of bone allograft. The mean follow-up was 7.2 years (1.6 to 9.7). All patients were assessed according to the American Academy of Orthopedic Surgeons (AAOS) classification of bone loss, the amount of bone graft required, thickness of the graft layer, signs of graft incorporation and use of augmentation. A total of 20 acetabular components required re-revision for aseptic loosening, giving an overall survival of 72% (95% CI, 54.4 to 80.5). Of these failures, 14 (70%) had an AAOS type III or IV bone defect. In the failed group, poor radiological and histological graft incorporation was seen. These results suggest that impaction allografting in acetabular revision with severe bone defects may have poorer results than have previously been reported.
26
THE SWEDISH TOTAL HIP REPLACEMENT REGISTER
Henrik Malchau, Peter Herberts, Thomas Eisler et al. · Journal of Bone and Joint Surgery · 2002 · 814 citations
Bone grafting in total hip replacement for acetabular protrusion
Tom J.J.H. Slooff, R. Huiskes, Jim van Horn et al. · Acta Orthopaedica Scandinavica · 1984 · 429 citations · Full text