We have shown that axial length and accordingly refractive status influenced peripapillary RNFL thickness measurements by Cirrus HD OCT in children. Therefore, to make a correct diagnosis of glaucoma or other optic neuropathies in children, either axial length-induced magnification effect should be corrected by ophthalmologists or the current Cirrus HD OCT database should be revised taking axial length into consideration.