Proceedings of the National Academy of Sciences · 2006 · 619 citations · 14 references
EngineeringBioengineeringHematologySeparation ProcessesSeparation ScienceTransfusion MedicineBlood CollectionBlood PhysiologyMicrofluidic Device FabricationMicrofluidic DevicesMicrofluidic SystemsMicrofluidicsBlood Component SeparationHydrodynamicsMicrofluidic Cell SeparationMicrofluidic SeparationMicrofluidic Separation TechniquesPlatelet SeparationRed Blood Cell SeparationWhole Blood Separation
We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 microm/sec and volume rates up to 1 microl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma.
14
Continuous Particle Separation Through Deterministic Lateral Displacement
Lotien Richard Huang, Edward C. Cox, Robert H. Austin et al. · Science · 2004 · 1.6K citations
Separation of Blood Leucocytes, Granulocytes and Lymphocytes
Arne Bøyum · Tissue Antigens · 1974 · 669 citations
Pharmacy, Hematology, Immunology +15
Critical particle size for fractionation by deterministic lateral displacement
David W. Inglis, John A. Davis, Robert H. Austin et al. · Lab on a Chip · 2006 · 418 citations
Design Principles of Vascular Beds
Axel R. Pries, Timothy W. Secomb, P. Gaehtgens · Circulation Research · 1995 · 326 citations
Morphometry of human leukocytes