Clinical Oral Implants Research · 2010 · 145 citations · 45 references
DentistryPeriodonticsPeriodontologyDental MaterialsPeriodontal EpidemiologyPeriodontal PathogenesisImplant-associated InfectionMicrobiological AnalysisMicrobiological SamplingPeriodontal DiseasePeriodontal MicrobiologyPeriodontal Pocket FormationCeramic AbutmentsDental ImplantsImplant Surface ColonizationPeptostreptococcus MicrosPocket Depth MeasurementPrevotella IntermediaProbing Pocket DepthTitanium Abutments
AIM: To compare the early bacterial colonization and soft tissue health of mucosa adjacent to zirconia (ZrO(2)) and titanium (Ti) abutment surfaces in vivo. MATERIALS AND METHODS: Twenty edentulous subjects received two endosseous mandibular implants. The implants were fitted with either a ZrO(2) or a Ti abutment (non-submerged implant placement, within-subject comparison, left-right randomization). Sulcular bacterial sampling and the assessment of probing pocket depth, recession and bleeding on probing were performed at 2 weeks and 3 months post-surgery. Wilcoxon matched-pairs, sign-rank tests were applied to test differences in the counts of seven marker bacteria and the clinical parameters that were associated with the ZrO(2) and Ti abutments, at the two observation time points. RESULTS: ZrO(2) and Ti abutments harboured similar counts of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, Peptostreptococcus micros, Fusobacterium nucleatum and Treponema denticola at 2 weeks and 3 months. Healthy clinical conditions were seen around both ZrO(2) and Ti abutments at all times, without significant differences in most clinical parameters of peri-implant soft tissue health. Mean probing depths around Ti abutments were slightly deeper than around ZrO(2) abutments after 3 months (2.2 SD 0.8 mm vs. 1.7 SD 0.7 mm, P=0.03). CONCLUSIONS: No difference in health of the soft tissues adjacent to ZrO(2) and Ti abutment surfaces or in early bacterial colonization could be demonstrated, although somewhat shallower probing depths were observed around ZrO(2) abutments after 3 month.
45
Defining the healthy "core microbiome" of oral microbial communities
Egija Zaura, Bart J. F. Keijser, Susan M. Huse et al. · BMC Microbiology · 2009 · 1.4K citations · Full text
Effect of material characteristics and/or surface topography on biofilm development
Wim Teughels, Nele Van Assche, I. Sliepen et al. · Clinical Oral Implants Research · 2006 · 1.3K citations · Full text
The soft tissue barrier at implants and teeth
Tord Berglundh, Jan Lindhe, I. Ericsson et al. · Clinical Oral Implants Research · 1991 · 891 citations
Shuichiro Shiina, Hiromu Aoyama, Yasushi Shiratori et al. · Investigative Radiology · 1990 · 655 citations
Veterinary Medicine, Veterinary Pathology, Veterinary Pharmacology +13