Vacuum phototriodes for the CMS electromagnetic calorimeter endcap

K. W. Bell, R. M. Brown, D. J. A. Cockerill, P. Flower, P. R. Hobson, B. W. Kennedy, A.L. Lintern, C. Selby, Omar Sharif, M. Sproston,

IEEE Transactions on Nuclear Science · 2004 · 72 citations · 2 references

DOIFull text

Open access

Concepts

Abstract

The measurement of scintillation light from the lead tungstate crystals of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) poses a substantial technical challenge, particularly in the endcap regions, where the radiation levels are highest. The photodetectors must be fast, sensitive, radiation-hard, and operate with significant internal gain in a magnetic field of 4 Tesla. The measured performance characteristics of the first batches of series production vacuum phototriodes (VPT), developed to satisfy the needs of CMS, will be described.