2014 · 16 citations · 6 references
EngineeringBioengineeringBiomedical EngineeringBiomemsBiosensorsSensorsBiosensor DesignDna SequencingImage SensorsNucleic Acid BiosensorsNucleic Acid SequencingCmos Image SensorsCorrelated Double SamplingDna SensorsDouble SamplingField-effect Transistor BiasingField-effect Transistor SensorsImage Sensor DesignIon-selective Field-effect Transistor Sensors
A 64×64 CMOS ion-image sensor is demonstrated towards accurate high-throughput DNA sequencing. Dual-mode (pH/image) sensing is performed with ion-sensitive field-effect transistor (ISFET) fabricated in standard CMOS image sensor (CIS) process. After addressing physical locations of DNA slices by optical contact imaging, local pH for one DNA slice can be mapped to its physical address with accurate correlation. Moreover, pixel-to-pixel ISFET threshold voltage mismatch is reduced by correlated double sampling (CDS) readout. Measurements show a sensitivity of 103.8mV/pH and fixed-pattern-noise (FPN) reduction from 4% to 0.3% with speed of 1200fps.
6
An integrated semiconductor device enabling non-optical genome sequencing
Jonathan M. Rothberg, Wolfgang Hinz, Todd M. Rearick et al. · Nature · 2011 · 2.2K citations · Full text
Simultaneous DNA amplification and detection using a pH-sensing semiconductor system
C. Toumazou, Leila Shepherd, Samuel C Reed et al. · Nature Methods · 2013 · 356 citations