IEEE Transactions on Industrial Electronics · 1994 · 194 citations · 6 references
EngineeringElectrical EngineeringAutomationElectric MachinesMachine DesignDrive SystemsElectric DrivesElectric Motor DrivesElectric MotorsInduction MachinesLosses In Electric MachinesDynamic ResponseInduction Motor DrivesIron LossesLoss AnalysisLoss MinimizationLoss Minimization ControlLoss Reduction TechniquesMotor Losses
The induction motor (IM) is a high-efficiency machine when working close to its rated operating point. However, at torques and/or speeds far from the rated values the efficiency is greatly reduced. In this work a new approach is proposed that minimizes the total copper and iron losses in a variable speed and/or torque IM drive, while keeping a good dynamic response. This method is based on a simple IM model that includes iron losses. The model, which only requires the knowledge of conventional IM parameters, is referred to a field-oriented frame. Using this model, the IM losses are quantified and an algorithm, based on a field-oriented scheme, is deduced. Simulation and experimental results are presented to validate the proposed method.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6