Journal of Physics D Applied Physics · 2007 · 98 citations · 17 references
Natural SciencesMaterials EngineeringMaterials ScienceElectrochemistrySurface ScienceThin FilmsElectrical CharacterizationSurface ChargeThin Film Electrical PropertiesCorona ChargingMultilayer MaterialsMultilayer StacksPolyethyleneSurface Charge MeasurementSurface PotentialSurface Potential AnalysisSurface Potential Measurement
This paper describes a study on the surface potential decay of corona charged low density polyethylene (LDPE) films. A conventional corona charging process is used to deposit charge on the surface of film and surface potential is measured by a compact JCI 140 static monitor. The results from corona charged multilayer sample reveal that the bulk process dominates charge decay. In addition, the pulsed-electro-acoustic (PEA) technique has been employed to monitor charge profiles in corona charged LDPE films. By using the PEA technique, we are able to monitor charge migration through the bulk. Charge profiles in corona charged multilayer sample are consistent with surface potential results. Of further significance, the charge profiles clearly demonstrate that double injection has taken place in corona charged LDPE films.
17