Concepedia

Publication | Closed Access

Durability Studies of PBI‐based High Temperature PEMFCs

307

Citations

24

References

2008

Year

Abstract

Abstract Long‐term durability testing of polybenzimidazole (PBI)‐based polymer electrolyte membrane (PEM) fuel cells was performed using test protocols designed to simulate fuel cell operational situations which may be found in real applications. The fuel cell voltages and phosphoric acid (PA) loss were carefully monitored over thousands of hours and hundreds of cycles. In the typical operating range for high temperature PEM fuel cells (160 °C), the fuel cell voltage degradation rate was 4.9 μV h –1 for steady‐state operation. The PA loss rates were generally low and indicated that long‐term operation (>10,000 h) was possible without significant performance degradation due to PA loss from the membrane. Dynamic durability tests also showed that the PA loss rate from the membrane electrode assemblies (MEAs) depended on cell operating temperature and load conditions. Under all conditions, the PA loss was a relatively small amount of the total PA in the membrane.

References

YearCitations

Page 1