Journal of Magnetic Resonance Imaging · 2015 · 15 citations · 20 references
MedicineDiagnostic SciencesRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiovascular ImagingVascular ImagingComparative Diagnostic PerformanceContrast-enhanced AngiographyContrast-enhanced Magnetic Resonance AngiographyImage Acquisition QualityMagnetic Resonance AngiographyNoncontrast Vascular ImagingNoninvasive Vascular ImagingVascular Stenosis Assessment
BACKGROUND: To evaluate the feasibility and diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) MR angiography (MRA) for imaging infragenual arteries at 3.0T, with contrast enhanced MR angiography (CE MRA) as reference. METHODS: Twenty consecutive patients with suspicion of lower extremity arterial disease undergoing routine CE MRA were recruited. FSD MRA was performed at calf before CE MRA. Image quality and stenosis degree of infragenual arteries from both techniques were independently evaluated and compared. Six patients in this study underwent DSA examination. RESULTS: Three undiagnostic segments were excluded with severe venous contamination in CE MRA. A total of 197 calf arterial segments images were analyzed. No significant difference existed in the relative signal intensity (rSI) of arterial segments between FSD MRA and CE MRA techniques (0.92 ± 0.09 versus 0.93 ± 0.05; P = 0.207). However, the subjective image quality score was slightly higher in FSD MRA (3.66 ± 0.81 versus 3.49 ± 0.87; P = 0.050). With CE MRA images as reference standard, slight overestimation existed in FSD MRA (2.19 ± 1.24 versus 2.09 ± 1.18; P = 0.019), with total agreement of 84.3% on the basis of all arterial segments. The sensitivity, specificity, negative predictive value, and positive predictive value of FSD MRA was 96.4%, 93.0%, 98.5%, and 84.1%. No significant difference in the stenosis degree score was detected between MRA (FSD MRA and CE MRA) and DSA (P > 0.05). CONCLUSION: FSD MRA performed on at 3.0T without the use of contrast medium provides diagnostic images allowing for arterial stenosis assessment of calf arteries that was highly comparable with CE MRA. Moreover, venous contamination was less problematic with FSD MRA.
20
Peter Marckmann, Lone Skov, Kristian Rossen et al. · Journal of the American Society of Nephrology · 2006 · 1.4K citations
Medicine, Nephrology, Radiology +10
Alan T. Hirsch, Ziv J. Haskal, Norman Hertzer et al. · Journal of Vascular and Interventional Radiology · 2006 · 460 citations · Full text
Medicine, Cardiology, Surgery +17
Projective Imaging of Pulsatile Flow with Magnetic Resonance
Van J. Wedeen, Reto Meuli, Robert R. Edelman et al. · Science · 1985 · 262 citations
Robert R. Edelman, John J. Sheehan, Eugene Dunkle et al. · Magnetic Resonance in Medicine · 2010 · 177 citations · Full text