Our results demonstrated sustained increases in tissue rSO(2) values following peripheral nerve block placement, in addition to higher initial rSO(2) values in operative limbs prior to block placement. Further investigations are necessary to define the expected baseline rSO(2) values in operative and control limbs. Future efforts utilizing NIRS-based detection of tissue ischemia should consider the small but significant changes in rSO(2) resulting from a successful nerve block.