Evaluation Of Ozone/Biological Treatment For Disinfection Byproducts Control And Biologically Stable Water

Michael Price, Robert W. Bailey, Andrew K. Enos, Mark Hook, Slawomir W. Hermanowicz

Ozone Science and Engineering · 1993 · 51 citations · 3 references

Concepts

Abstract

Abstract Impacts of ozonation followed by biological filtration on the formation of disinfection byproducts and the production of biologically stable water were studied on pilot plant and full-scale at two U.S. locations (Oakland, CA and Tampa, FL). Also evaluated is a method to estimate bacterial regrowth potential by comparing it to assimilable organic carbon (AOC) measurements. At both locations, settled plant water is diverted to the pilot plant where it is split into two parallel trains. One train is ozonated, then Filtered through anthracite/sand dual media followed by GAC or through a GAC/sand dual media filter. The other train (control) is identical except that the water is not ozonated. The full scale plants have sedimentation, ozonation, then GAC/sand filtration. Keywords: OzoneBiological TreatmentBiological Activated CarbonDisinfection Byproducts ControlBiologically Stable WaterTrihalomethanesAssimilable Organic CarbonBacterial Regrowth PotentialTHM Formation PotentialChlorine DemandAldehydesOzonation Byproducts

References

3