Clinical Chemistry · 2002 · 846 citations · 33 references
Health ProfessionsClinical SciencesClinical MedicinePatient SafetyTransfusion MedicineBlood Transfusion SafetyDiagnostic ErrorDiagnostic Error DetectionError AnalysisMeasurement ErrorClinical Laboratory Error ReportingHeterogeneityLaboratory Data ReviewLaboratory ProcedureLaboratory ReportsLaboratory Result Discrepancy DetectionLaboratory Result MisinterpretationLaboratory Test Result Interpretation
BACKGROUND: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion. METHODS: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected. RESULTS: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of "laboratory error" (also referred to as "blunder", "mistake", "problem", or "defect"). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13-32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents. CONCLUSIONS: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.
33
Mistakes in a stat laboratory: types and frequency
Mario Plebani, Paolo Carraro · Clinical Chemistry · 1997 · 570 citations · Full text
Health Professions, Internal Medicine, Quality Management +12
Transfusion errors in New York State: an analysis of 10 years' experience
Jeanne V. Linden, Kathleen Dorman Wagner, Anthony E. Voytovich et al. · Transfusion · 2000 · 412 citations
Medicine, Hematology, Mistake +8
Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports
L. M. Williamson, Sarina C. Lowe, Elizabeth M. Love et al. · BMJ · 1999 · 339 citations · Full text
Philippe Baele, Marie Bruyère, Véronique Deneys et al. · Vox Sanguinis · 1994 · 125 citations