A method of defining the load impedance specification for a stable distributed power system

C.M. Wildrick, F.C. Lee, Byungcho Choi

IEEE Transactions on Power Electronics · 1995 · 511 citations · 1 references

Concepts

Abstract

By applying the loop gain analysis technique, a forbidden region for the polar plot of the ratio of impedances at the interface between two cascaded power subsystems is determined. A method of transforming the forbidden region into a load impedance specification for a given source impedance is developed. The method assures system stability and minimal performance degradation of the distributed power system, while allowing impedance overlap at the interface.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>