IEEE Transactions on Applied Superconductivity · 2004 · 15 citations · 1 references
Natural SciencesElectrical EngineeringMaterials ScienceElectronic MaterialsMagnetic MaterialsMetallic MaterialsAlloysFerromagnetic MaterialsMagnetic CharacterizationMagnetic Circuit AnalysisMetalsSuperconducting MaterialsCritical Magnetic FieldCritical TemperatureData ProcessingExperimental Data CollectionInsert Coil DesignMagnetic Materials CharacterizationUpper Critical Field
The magnetic field and temperature characteristics I/sub c/(T, B) are important for practical application. This work presents the results of investigations on I/sub c/(T, B) for a strand based on Nb-47.5 wt% Ti alloy. The strand is used in the cable of the ITER PF insert coil, which is under construction. The measurements were carried out in magnetic fields up to 9 T and in the range of temperatures from 4.2 K to 7 K. The critical temperature T/sub c/(B) was determined from voltage-temperature characteristics (VTC) taken in magnetic fields. The temperature dependencies of the upper critical field B/sub c2/(T) were analyzed. By experimental data processing and analysis of literature, relationships describing B/sub c2/(T) and I/sub c/(B, T) dependencies have been defined. Processing programs were used, which allow obtaining all fitting parameters of I/sub c/(T, B) relation.
1