IEEE Transactions on Industry Applications · 1993 · 50 citations · 6 references
EngineeringElectrical EngineeringPhysicsCircuit TheoryElectromagneticsPlasma PhysicsElectrostatic PrecipitationPlasma ElectrodynamicsCorona DischargesElectric Field DistributionElectrostatic PrecipitatorsIonizationIonization MechanismsPlate Electrostatic PrecipitatorsPrecipitator ModelingVoltage
A pure theoretical method for calculating the onset voltage of corona in duct-type electrostatic precipitators that is independent of the arrangement of discharge wires relative to the collecting plates is described. This method is based on a criterion for self-recurring single electron avalanches in a known electric field distribution in the ionization zone surrounding the discharge wire. The results computed by this method are in reasonable agreement with those measured experimentally.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6