Timing, Predictive Factors, and Prognostic Value of Cerebrovascular Events in a Large Cohort of Patients Undergoing Transcatheter Aortic Valve Implantation
417
Citations
37
References
2012
Year
In a large cohort of patients undergoing transcatheter aortic valve implantation, the rates of acute and subacute CVEs were 2.7% and 2.4%, respectively. While balloon postdilation and valve dislodgment/embolization were the predictors of acute CVEs, new-onset atrial fibrillation determined a higher risk for subacute events. Late events were determined mainly by a history of chronic atrial fibrillation and peripheral and cerebrovascular disease. The occurrence of major stroke was associated with increased early and late mortality. These results provide important insights for the implementation of preventive measures for CVEs after transcatheter aortic valve implantation.