European Journal of Cardio-Thoracic Surgery · 2008 · 31 citations · 15 references
MedicineCardiologySurgeryCardiothoracic SurgeryHemodynamic ManagementVascular SurgeryCardiac CatheterizationCardiopulmonary BypassThoracic SurgeryVenous AccessCannulation Success RatesFluid ExpansionGravity DrainageGravity Drainage DriveGravity Drainage MechanismsPump Flow DynamicsRedo Valve SurgeryVenous Return
OBJECTIVE: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery. METHODS: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation. RESULTS: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001). CONCLUSION: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.
15
Percutaneous Initiation of Cardiopulmonary Bypass
Steven J. Phillips, Bruce Ballentine, Dianne Slonine et al. · The Annals of Thoracic Surgery · 1983 · 212 citations
Medicine, Cardiology, Surgery +7
Mitral valve repair robotic versus sternotomy☆
Thierry Folliguet, Fabrice Vanhuyse, X CONSTANTINO et al. · European Journal of Cardio-Thoracic Surgery · 2006 · 87 citations · Full text
Medicine, Cardiology, Surgery +11
Temporary extracorporeal support of the right ventricle
Walter P. Dembitsky, Pat O. Daily, Aidan A. Raney et al. · Journal of Thoracic and Cardiovascular Surgery · 1986 · 38 citations
Medicine, Cardiology, Surgery +10