Quantification of stratum corneum removal by adhesive tape stripping by total protein assay in 96‐well microplates

F. Dreher, Bobeck S. Modjtahedi, Sara P. Modjtahedi, Howard I. Maibach

Skin Research and Technology · 2005 · 78 citations · 9 references

Concepts

Abstract

BACKGROUND/AIMS: Examination of stratum corneum (SC) content with tape stripping and a colorimetric method is increasingly used. We examined the possible use of microplates in tandem with a colorimetric method to examine SC removed with tape stripping. As a corollary to this examination, the homogeneity of tape strips was examined. METHOD: The commonly used Lowry assay was adapted for 96-well plates. Tapes were divided into four regions and sample disks of 5 mm diameter were taken from each and analyzed for SC mass using the adapted Lowry assay. RESULTS: Homogeneity of SC removal over different areas across a tape strip is limited. CONCLUSION: Quantification of SC by means of a 96-well microplate-based colorimetric method is feasible and shortens the time of analysis. However, when using D-Squame tape disks, SC removal on a limited area of the tape is not predictive for SC removal on the entire tape as removal is inhomogenous. Therefore, SC protein extraction should be performed on a large enough area, eventually on the entire tape when quantifying SC mass removed by tape stripping.

References

9