American Journal of Respiratory and Critical Care Medicine · 1998 · 533 citations · 27 references
MedicinePhysical MedicinePhysiologyExercise PhysiologyExercise TestingPulmonologyAerobic ExerciseCardiopulmonary Exercise TestingChronic Obstructive Pulmonary DiseaseExercise Pulmonary Function TestingExercise TrainingObstructive Lung DiseaseDynamic HyperinflationDynamic Hyperinflation During ExerciseExercise EnduranceLung HyperinflationRespiratory Mechanics During Exercise
Changes in lung hyperinflation, dyspnea, and exercise endurance are important outcomes in assessing therapeutic responses in chronic obstructive pulmonary disease (COPD). Therefore, we studied the reproducibility of Borg dyspnea ratings, inspiratory capacity (IC; to monitor lung hyperinflation), and endurance time during constant-load symptom-limited cycle exercise in 29 patients with COPD (FEV1 = 40 +/- 2% predicted; mean +/- SEM). Responsiveness was also studied by determining the acute effects of nebulized 500 micrograms ipratropium bromide (IB) or saline placebo (P) on these measurements. During each of four visits conducted over an 8-wk period, spirometry and exercise testing were performed before and 1 h after receiving IB or P (randomized, double-blinded). Highly reproducible measurements included: endurance time (intraclass correlation R = 0.77, p < 0.0001); Borg ratings and IC at rest, at a standardized exercise time (STD), and at peak exercise (R > 0.6, p < 0.0001); and slopes of Borg ratings over time, oxygen consumption (V O2), and ventilation (R > 0.6, p < 0.0001). Responsiveness was confirmed by finding a significant drug effect for: change (Delta) in endurance time (p = 0.0001); DeltaBorgSTD and DeltaBorg-time slopes (p < 0.05); and DeltaIC at rest, at STD, and at peak exercise (p = 0.0001). With all completed visits, DeltaBorgSTD correlated better with DeltaICSTD than any other resting or exercise parameter (n = 115, r = -0.35, p < 0.001). We concluded that Borg dyspnea ratings, and measurements of IC and endurance time during submaximal cycle exercise testing are highly reproducible and responsive to change in severe COPD.
27
Psychophysical bases of perceived exertion
Gunnar Borg · Medicine & Science in Sports & Exercise · 1982 · 16.4K citations
Standardization of Spirometry—1987 Update
American Review of Respiratory Disease · 1987 · 2.3K citations
Donald A. Mahler, David H. Weinberg, Carolyn K. Wells et al. · CHEST Journal · 1984 · 1.3K citations
Idelle M. Weisman, R. Jorge Zeballos · American Heart Journal · 1976 · 1.2K citations