Comment on “Steady state mass transfer from single‐component dense nonaqueous phase liquids in uniform flow fields” by T. C. Sale and D. B. McWhorter

P. Suresh C. Rao, James W. Jawitz

Water Resources Research · 2003 · 97 citations · 4 references

DOIFull text

Open access

Concepts

Abstract

[1] Sale and McWhorter [2001] presented an elegant mathematical analysis of an important environmental problem: evaluating the impacts of dense-nonaqueous phase liquid (DNAPL) source zone architecture on downgradient contaminant flux. One of their objectives was to evaluate potential benefits of partial removal of DNAPL mass through aquifer remediation efforts. They developed a numerical superposition scheme to model dissolution from heterogeneous DNAPL source zones in uniform flow fields. A major conclusion of their work was that significant improvements in groundwater quality would require the removal of the vast majority of the DNAPL mass. [2] We do not refute the methods or the results of their analyses; however, we do object to the conclusions drawn regarding groundwater quality improvements. Our main objection stems from their use of a uniform flow field. The results and conclusions would be quite different for nonuniform flow fields in heterogeneous formations. We are concerned that the conclusions presented by Sale and McWhorter [2001] may stifle DNAPL source remediation efforts that have potential benefits at many contaminated sites. Recent field studies have shown that DNAPL mass reductions, in the range of 70 to 90+%, are possible using in situ flushing approaches [Brooks, 2000; Fiorenza et al., 2000; Jawitz et al., 2000; Lowe et al., 2000]. We contend that in heterogeneous formations, significant contaminant flux reductions can be realized through partial mass reduction in DNAPL source zones. It is a matter of debate whether such contaminant flux reductions achieved are sufficient for risk reduction or regulatory compliance. Einarson and Mackay [2001] presented an analysis of risk reduction resulting from reduction of contaminant flux from a source zone. Rao et al. [2001] have presented arguments supporting the concept that contaminant flux reduction to achieve the condition of a stable (i.e., arrested) or shrinking dissolved plume should be considered as an appropriate performance metric for source zone remediation. [3] In support of our contention, we present here a simplified analytical approach to illustrate the benefits (i.e., contaminant flux reduction) resulting from partial DNAPL mass reduction in the source zone. We consider a heterogeneous flow domain that is represented by a collection of stream tubes, with no mass transfer across the stream tubes. We assume a log-normal distribution of stream tube velocities, f(v), and a homogeneous DNAPL distribution. [4] Sale and McWhorter [2001] studied homogeneous media with heterogeneous DNAPL, while here we consider heterogeneous media with homogeneous DNAPL. Of course, real contaminated sites exhibit heterogeneities in both the media properties and DNAPL spatial distributions. We present the heterogeneous media with homogeneous DNAPL case because the analysis is fairly simple, and because the results are supported by preliminary findings from ongoing analyses of three-dimensional numerical simulations, and recently completed controlled field experiments [Brooks, 2000]. Both the numerical simulations and field experiments are characterized by heterogeneous media and DNAPL distributions. [5] We consider an in situ flushing type of aggressive source zone remediation with the following simplifying assumptions: (1) there is initially DNAPL in each stream tube; (2) if a stream tube contains any DNAPL, the aqueous contaminant concentration is assumed to be the solubility limit, Cs, based on instantaneous, local equilibrium dissolution; (3) a stream tube is considered ‘clean’ when all of the DNAPL has been removed, and the aqueous contaminant concentration is zero in clean stream tubes; (4) during source zone remediation, flux injection results in a proportionately greater volume of flushing agents displaced through the high-velocity stream tubes; therefore the high-flux stream tubes are cleaned preferentially. Note that the location of DNAPL within the stream tube is immaterial to our analysis; only the presence of DNAPL somewhere in a given stream tube is used as a criterion for assigning the exit concentration as being equal to Cs. This is equivalent to the Sale and McWhorter [2001] analysis, where upgradient DNAPL subzones were shown to influence the dissolution of downgradient subzones. [7] Contaminant flux reduction, Ω, is plotted in Figure 1 as a function of DNAPL mass reduction, F, for a range of velocity distribution standard deviations. Significant contaminant-flux reductions may be effected through much lower mass reduction levels (Figure 1) than was implied by Sale and McWhorter [2001]. For the homogeneously distributed DNAPL scenario considered here, a decreasing fraction of high-velocity stream tubes contributes the bulk of the contaminant flux as the velocity variability increases. Preferential remediation of the high-velocity stream tubes, which contain a small fraction of the total DNAPL mass, results in a large reduction in contaminant flux. Thus, as velocity variability increases, lower contaminant mass reductions are required to achieve equivalent reductions in contaminant flux. [8] The general applicability of the approach presented here is limited by the assumption that DNAPL mass is only removed from the high-velocity stream tubes (i.e., mass is only removed from stream tubes that become completely clean). For example, Figure 1 indicates that as the velocity variance approaches zero, a reduction in DNAPL mass will result in a 1:1 reduction in contaminant flux. Because all of the stream tube velocities would be nearly equal, the remediation of a certain fraction of them would reduce the total contaminant flux by a similar fraction. However, if the velocities were all equal (i.e., homogeneous), flux-averaged in situ flushing would not result in the complete remediation of high-velocity stream tubes (as is assumed here), but would rather result in the partial removal of mass from each stream tube with no effect on the total contaminant flux. This conclusion is a restatement of that drawn by Sale and McWhorter [2001]. However, we suggest that the assumption that contaminant mass is removed only from the high-velocity stream tubes becomes increasingly reasonable as velocity variability increases. The simplified analysis presented here may only be appropriate for velocity variances above some threshold value, but we contend that it demonstrates that significant contaminant-flux reductions can be achieved through partial source-zone remediation. [9] We have considered homogeneous DNAPL distribution, but in a heterogeneous formation DNAPL saturation may be correlated to the hydraulic conductivity. A positive correlation between DNAPL mass and hydraulic conductivity leads to even greater contaminant-flux reduction than the base uncorrelated case [Berglund, 1997]. Our assumption of equilibrium dissolution results in larger contaminant concentrations and larger estimated contaminant fluxes than might be observed. Note also that in this analysis, we have assumed that DNAPL mass is removed only from stream tubes with v > vmax.. We recognize that additional DNAPL mass will be removed from the other stream tubes (v < vmax); but, consideration of this aspect is left for future development. [10] While we agree with Sale and McWhorter [2001] that DNAPL source zone architecture is important, we contend that failure to consider the nature of the changes in the source zone architecture caused by in situ aggressive remediation in heterogeneous formations can lead to an underestimation of the potential benefits associated with such changes.

References

4