Journal of Bridge Engineering · 2005 · 109 citations · 10 references
EngineeringMaterials EngineeringMaterials ScienceBuilding StructuresStructural EngineeringStructural MaterialsBridge RetrofittingComposite StructuresFiber-reinforced CompositesReinforced Concrete StructuresStructural RetrofittingStructural SystemsComposite Reinforcement SystemsComposite Retrofit SystemsFastenersFatigue PerformanceFiber-reinforced Polymer CompositesMechanical FastenersReinforced ConcreteRetrofit
Flexural retrofitting of concrete bridge girders has largely relied on adhesive‑applied FRP systems, whose performance is governed by bond quality and substrate stress transfer, and a newer powder‑actuated fastener (PAF) approach has received limited study. This study compares the static and fatigue performance of concrete beams retrofitted with conventional adhesive (CAA), near‑surface mounted (NSM), and powder‑actuated fastener (PAF) FRP systems. Ten medium‑scale beams—six strengthened (two per retrofit method) subjected to cyclic loading and four (one per method plus a control) tested to monotonic failure—were used to evaluate the retrofit systems. All three FRP methods significantly increased monotonic strength over the control, yet NSM and PAF outperformed CAA under cyclic loading, with clear evidence of midspan FRP debonding before failure.
The majority of experimental work involving the flexural retrofit of concrete bridge girders has been conducted on beam specimens with adhesive-applied, soffit-mounted, fiber-reinforced polymer (FRP) composite systems, referred to in this study as conventional adhesive application (CAA). It has been observed that the performance of such girders is often controlled by the quality of the bond between the FRP and the concrete substrate and the substrate's ability to transfer stress from the steel to the FRP. With the goal of improving the performance of bonded FRP in mind, two additional soffit-mounted retrofit schemes are investigated: near-surface mounted (NSM), where the FRP strips are embedded in adhesive within slots cut into the substrate concrete, and, powder-actuated fastener-applied (PAF) FRP, which uses a powder-actuated nail gun to install mechanical fasteners through predrilled holes in the FRP into the concrete substrate, "nailing" the FRP in place. The PAF application is a recent development, and little work has been done on it other than by the proprietors of the system. This study reports on a comparative study of the static and fatigue performance of reinforced concrete beams retrofitted with CAA, NSM, and PAF FRP retrofit systems. Ten medium-scale beams were tested: six strengthened specimens, two per retrofit method, were tested under cyclic loading conditions, and four specimens, one per retrofit method and one control specimen, were tested monotonically to failure. The results of this study indicate that although all three methods of FRP application result in significant strength increases over the control specimen under monotonic loading conditions, the CAA method is outperformed by the other methods under cyclic conditions. A number of other relevant detailed conclusions with respect to performance and practical application issues are presented for each of the methods of retrofit examined in this study. Significantly, clear evidence of FRP debonding in the midspan region prior to specimen failure is presented.
10