Acta Orthopaedica Scandinavica · 1992 · 131 citations · 7 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomaterialsOrthopedicsRheumatologyIntra-articular TherapyJoint DiseaseJoint PathologyJoint SurgerySynovial InflammationInternal Fixation DevicesKnee Osteochondral LesionsKnee SynovitisOsteochondral InjuriesOsteochondrosis DissecansSynovial Inflammatory Injury
Biodegradable rods made of polyglycolide (Dexon, Biofix) or lactide-glycolide copolymer (Vicryl) have been used for the past 5 years for internal fixation of a variety of fractures and osteotomies (Böstman et al. 1989, 1990b). Experience from using such rods for fixation of intraarticular osteochondral lesions seems to be less extensive. We report a case of severe synovial reaction to biodegradable rods used for fixation of osteochondritis dissecans of the knee and discuss possible reasons for the increased risk of foreign-body reactions when these rods are used intraarticularly.
7
Immune response to polyglycolic acid implants
Seppo Santavirta, Konttinen Yt, T Saito et al. · Journal of Bone and Joint Surgery - British Volume · 1990 · 158 citations